Performance Test

performance tests

TEST SUMMARY: NanoQ-14 at room temperature was loaded with two ICE containers (frozen water) and PAYLOAD container (1) and then placed in test oven. The test environment was programed to maintain a temperature of continuos 32C (+/- .5C) for the duration of the test period of 14 days. Thermocouples were mounted to monitor the internal temperature of the liquid payload and the air within the payload. The ice containers were frozen in a conventional freezer for 24 hrs prior to installation of the test. The ice containers were removed from the freezer and placed directly into the NanoQ without preconditioning. The temperature of the ice containers was -10.8C. A simulated payload of 2L of water was preconditioned to 6C prior to placement into the NanoQ. Testing performed by Cascade Technical Sciences, Inc.

The Problemcontact us